B3-32DW 20 Plate Double Wall Heat Exchanger

• 11.25" x 4.56" SS316L Inner Plates

• 0.64 m² Total Surface Area

• 316 Stainless Steel, Copper Brazed

Select an option from below:
Quantity
Price Each:
1+
328.91
In stock
QTY
Item Pictures
B3-32DW 20 Plate Heat Exchanger Double Wall Potable Water B3-32DW 20 Plate Heat Exchanger Double Wall Potable Water
B3-32DW 20 Plate Heat Exchanger Double Wall Potable Water B3-32DW 20 Plate Heat Exchanger Double Wall Potable Water

Item Description

Heat Exchanger Dimensions

Plate Heat Exchanger Specifications by Model

Model
A
B
C
D
F
H
Weight
Volume per Channel
Unit Heat Exchanger Area
Design Pressure
Refrigeration Capacity
Max Number of Plates
Max Connection Size
mm
kg
Liters
m2
Mpa
KW
B3-5A
135
40
104
18
5
4.7+1.8xNP
0.04+0.0021xNP
0.006
0.005
3.0
1-5
30
1/4" NPT
B3-12A
199
85
154
40
7
13+2.34xNP
0.4+0.044xNP
0.018
0.012
1.0
1-6
60

3/4" NPT
7/8" Welded

B3-14DW
196
86
156
46
7+2.35xNP
0.4+0.096xNP
0.022
0.014
B3-16A
220
90
180
52
7+2.24xNP
1.1+0.06xNP
0.029
0.016
2-8
B3-23A
315
73
278
40
1.2+0.07xNP
0.040
0.023
3-10
B3-27A
286
116
234
63
7+2.4xNP
1.3+0.125xNP
0.050
0.027
3.0
5-20
120

1-1/4" NPT

B3-32A
243
72
1.3+0.126xNP
0.032

1" NPT
1-1/8" Welded

B3-32DW
10+2.42xNP
1.3+1.52xNP
B3-36A
466
73
432
40
7+2.24xNP
1.3+0.106xNP
0.063
0.036
4-15

3/4" NPT
7/8" Welded

B3-52A
523
107
466
50
15+2.4xNP
1.5+0.23xNP
0.094
0.052
10-70

1" NPT
1-1/8" Welded

B3-60A
529
124
478
73
7+2.4xNP
2.7+0.26xNP
0.111
0.060
160
 
B3-63A
390
200
298
120
7+2.55xNP
5.5+0.27xNP
0.128
0.063
B3-95A
616
191
519
92
7+2.4xNP
7.8+0.42xNP
0.250
0.095
30-200
200

2" Threaded
2-1/8" Welded

B3-105A
528
246
430
148
9.5+0.46xNP
0.290
0.105
2.0
280

3" Threaded

B3-115A
535
253
456
174
15+2.4xNP
14+0.424xNP
0.250
0.115
3.0

2" Threaded
2-1/8" Welded

Conversion
1" = 25.4mm
1 kg = 2.2 lb
1 Liter = 0.264 Gallons
1m2 = 10.76ft2
1 Mpa = 145 psi
1 KW = 3412 Btu/h
 

 

General Specifications of Duda Energy Plate Heat Exchangers

Plate Material SUS304, SUS316 for Double Wall Units & Nickel Brazed
Welding Material B3=99.9% Copper, B4=99.9% Nickel
Mounting Studs B3-5A & B3-12A use M5-0.8, Larger units use M8-1.25
Flow Direction A Type: F1-F3, F2-F4
UL Listing TUVReinland ISO9001:2000

Corrosion:

304 Stainless Steel has good general corrosion resistance to a range of organic and in-organic fluids. It will have poor resistance to sulfuric and hydrochloric acids. Crevice corrosion may also occur when chlorides (salts) are present in the fluid. Since chlorides are in all natural sources of water it is best to use distilled water whenever possible. Typically, a unit will last about 10-15 years with regular tap water depending on salt content. With water containing chlorides or salt water, the life expectancy of the heat exchanger is reduced to about 3-5 years of continuous use, depending on the quality of the water. It is best to clean the units by back flushing with fresh water if highly contaminated fluids are used.

316 Stainless Steel is used in special applications where the working fluid may attack 304 stainless stee lmore aggressively.

Nickel brazed heat exchangers are designated with a B4 model code.They are used in applications where copper is not suitable for the working fluid. All nickel brazed heat exchangers use SUS316 plates.

Efficiency:

Use plate heat exchangers in a counter-flow configuration for highest efficiency. This allows the possibility of the cold fluid exit temperature to reach the temperature of the hot fluid inlet temperature.

Plate heat exchangers mostly utilize convection for their efficiency. Faster flow rates with more contact time (length of unit) will result in higher efficiency. More plates and more width is used mostly for reducing pressure drop through the units. While more plates or an increase in the width of the plates may add some additional efficiency, it is due to more surface area contact and less velocity through the plus, thus reducing convection efficiency. Always choose a unit with more length for more efficiency unless less pressure drop is crucial.

If you have a specific application with specific requirements to meet, it is recommended to fill out a sizing request on our heat exchanger sizing form.

Custom Heat Exchangers:

For model/plate/fitting combinations which we do not normally stock, we can also produce custom units with some lead time.Contact us for details.

 

Average Rating: Not yet rated

Write a review

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

Customer Reviews:

© 2008 DudaDiesel.com | Biodiesel & Alternative Energy Supplies